REZNOR® UDAS-125 V3 Low Static Gas Fired Unit Heater, 120000 BTU/hr, 115 VAC, Liquid Propane, Natural Gas Gas

REZUDAS125LVENT MFG #: UDAS-125
  • Amperage Rating: 5.1 A
  • Capacity: 120,000 BTU/hr
  • Frequency Rating: 60 Hz
  • Power Rating: 354 W
  • Voltage Rating: 115 VAC
  • Dimensions: 23-1/8 in H x 26-5/8 in W
  • Finish: Glossy White
  • Flow Rate: 1537 cfm
  • Gas Connection: 1/2 in
  • Gas Type: Liquid Propane / Natural Gas
  • Manufacturer: NORTEK GLOBAL HVAC
  • Manufacturer #: UDAS-125
  • Mounting Type: Ceiling
  • Series: V3
  • temHeatingCapacity: 120,000 BTU/hr
  • Temperature Rating: 50 to 60 deg F
  • Type: Low Static
Reznor's V3 Series UDAS gas-fired separated combustion unit heaters are available in 14 sizes ranging from 30,000 to 400,000 btu/h gas input (Sizes 30-125 are approved for residential application). Model UDAS heaters are designed for 82 to 83 percent thermal efficiency and are approved for installation in the United States and Canada by the Canadian Standards Association (CSA). The first ever separated combustion system in the commercial/industrial heating industry was introduced on a Reznor heater in the 1960's, and that proven technology is continued in this new separated combustion product. Model UDAS separated combustion units require installation of a specially designed combustion air/vent system including the unique concentric adapter box that allows for only one building penetration for both the vent and combustion air.

REZNOR® Gas Fired Unit Heater, Low Static, Series: V3, 120000 Btu/hr Capacity, 115 VAC, 5.1 A, 60 Hz Frequency, 354 W Power, 1537 cfm Flow Rate, Liquid Propane, Natural Gas Gas, 1/2 in Gas Connection, 50 to 60 deg F, Ceiling Mounting, Glossy White, 23-1/8 in H x 26-5/8 in W Dimensions
  • Features
  • Sizes 30 to 125 certified for residential heating application
  • Sizes 30 to 400 certified for commercial/industrial heating application
  • 82 to 83 % thermal efficient
  • 50 to 60 deg F rise range
  • New T-core 2 design titanium stabilized aluminized steel heat exchanger (patent pending)
  • New T-core 2 single burner combustion system including a one-piece burner assembly (patent pending)
  • 115/1/60 supply voltage
  • 115 V open fan motor with internal overload protection
  • Transformer for 24 V controls
  • Integrated circuit board with diagnostic indicator lights
  • Multi-try direct ignition with 100 % lockout
  • Fan relay (included on the circuit board)
  • Natural or propane single-stage gas valve (field adjustable for operation to 9000 ft elevation)
  • Vibration/noise isolated fan and venter motors designed for low noise operation
  • 2-pt and 4-pt suspension standard on all sizes
  • External terminal strip for 24 V wiring
  • External gas connections
  • Full fan guard engineered for safety
  • Improved cabinet design with less visible hardware and a new reznor appearance, Selection of either a horizontal or vertical combustion air/vent kit is required
  • 120000 Btuh or 35.2 kw/h heat capacity