Oatey® FlowGuard Gold® 31918 1-Step All Weather CPVC Cement With Ultraviolet Indicator, 16 oz, Translucent Liquid, Yellow, 0.94

OAT31918 MFG #: 31918
  • Color: Yellow
  • Container Size: 16 oz
  • Form: Translucent Liquid
  • Specific Gravity: 0.94
  • Curing Time: 1 or 6 hr
  • Flash Point: 14 to 23
  • Manufacturer: OATEY
  • Manufacturer #: 31918
  • Net Weight: 1.229
  • Odor / Scent: Solvent
  • Setting Time: 4 to 5
  • Suitable For Use With: Hot and Cold Water System
  • Temperature Rating: 0 to 115 degF
  • Type: 1-Step
  • VOC Content: 470
Oatey® FlowGuard Gold® All Weather CPVC Cement with UV Indicator is recommended for cold water systems and hot water systems up to 200°F / 93°C. Its UV indicator allows for quick and easy inspection of dry fit joints using any ultraviolet light source. Its medium body has excellent gap filling properties and is easy to apply with included in-lid dauber. This yellow, low VOC, fast set cement can be used to solvent weld copper tube sizes (CTS) CPVC hot and cold potable water pipes and fittings up to 2 in. diameter with interference fit. Oatey products have earned the trust of plumbing professionals for over 100 years.

Oatey® FlowGuard Gold® All Weather CPVC Cement, 1-Step, 16 oz, 1.229 lb Net Weight, For Use With: Hot and Cold Water System, Translucent Liquid, Yellow, Solvent, 470 g/L VOC, 14 to 23 deg F Flash, Composition: Furan, Tetrahydro, Methyl Ethyl Ketone, Ethene, Chloro-, Homopolymer, Chlorinated, Acetone, Cyclohexanone, Silica, Amorphous, Fumed, 0.94 Specific Gravity, 4 to 5 min Setting Time, 1 or 6 hr Curing, 0 to 115 deg F
  • Features
  • Product Videos
  • All weather yellow cement solvent welds CPVC, dauber included
  • For cold and hot water systems up to 200°F / 93°C
  • Allows for quick, easy inspection of dry fit joints with UV light
  • Can be used on copper tube sizes (CTS) CPVC hot and cold potable water pipes and fittings up to 2 in. diameter with interference fit
  • Approved for use with FlowGuard Gold® piping systems (registered trademark of The Lubrizol Corporation)
  • Recommended application temperature of 0°F to 115°F / -17°C to 46°C
  • No primer needed where local codes permit
  • Low VOC, high performance solvent cement that meets California South Coast Air Quality Management Districts (SCAQMD) 1168/316A or BAAQMD Method 40 requirements, meets ASTM Standard F493 and complies with NSF/ANSI 61 health effects requirements
  • 7.98 +/- 0.2 lbs/gallon density
  • 1 hr Cold/6 hr hot water above 6 deg F curing
  • 4 to 5 min (3 to 5 deg F)/2 to 3 min (5 to 7 deg F)/1 to 2 min (7 to 9 deg F) setting