Honeywell SuitePRO™ TB8575A1000/U Fan Coil Thermostat, Import
HONTB8575A1000U
MFG #: TB8575A1000/U
- Domestic / Import: Import
- Color: Premier White®
- Dimensions: 5-13/16 in W x 1-1/8 in D x 3-13/16 in H
- Display Type: LCD
- Manufacturer: Honeywell
- Manufacturer #: TB8575A1000/U
- Mounting Type: Horizontal / Vertical
- Series: TB8575A
- Voltage Rating: 20 to 30
TB6575A, TB6575B and TB8575A are a family of Digital Fan-Coil thermostats, that provide line/low voltage on/off control for various fan-coil units in residential and commercial applications. Great for use in hotels, condos and school classrooms.
SuitePRO™ Fan Coil Thermostat, Series: TB8575A, 20 to 30 VAC, LCD, Horizontal/Vertical Mount, Premier White®, 5-13/16 in W x 1-1/8 in D x 3-13/16 in H, Import
SuitePRO™ Fan Coil Thermostat, Series: TB8575A, 20 to 30 VAC, LCD, Horizontal/Vertical Mount, Premier White®, 5-13/16 in W x 1-1/8 in D x 3-13/16 in H, Import
- Features
- Simple, intuitive user interface and ease of installation
- Attractive modern styling ideal for hotels and condos
- Digital display of ambient operating temperature, set point, mode icons when cooling or heating relays operate, when energy savings mode is active and fan status
- Four buttons allow manual control of system operation, fan speed and temperature set point adjustment
- VersaSpeed ™ fan ramp algorithm automatically adjusts low, medium, high fan speed
- Activity sensing algorithm sets back thermostat to economy mode
- External energy savings input from dry contact such as time switch, occupancy sensor or hotel cardkey overrides comfort set point with selectable setback heating or cooling set points
- Energy savings input configurable as a normally open or normally closed dry contact
- Proportional plus integral (P+I) control algorithm for precision temperature regulation
- Adjustable deadband, in auto changeover mode, for heat and cool control
- Adjustable maximum heating and minimum cooling set point limits
- EEPROM permanently retains user settings, including set points, during power loss (no batteries required)
- Capability to display temperature sensor failure for easier troubleshooting
- Horizontal mounting on 2 x 4 in single gang electrical box, vertical mounting 2 x 4 in or 4 x 4 in junction box with optional wall plate (50033847-001)
- Electrical ratings - 24 VAC fan rating - 1.0 A, relay rating - 1.0 A
- 50/60 Hz frequency
- 5 to 95% RH non-condensing operating humidity
- Off-heat-cool-auto switch positions (system)
- Hi-med-low-auto-off switch positions (fan)
- Auto/manual changeover