BMPLUS-3000 3 Zone Two Stage Control Panel, 24 volt, Dual Fuel and Heat Pump Compatible
EWCBMPLUS3000
MFG #: BMPLUS-3000
- Color: Clear
- Height: 9-7/8 in
- Voltage Rating: 18 to 30 VAC, 24 VAC
- Changeover: Auto
- Dimensions: 10 in W x 1-7/10 in D x 9-7/8 in H
- Manufacturer: EWC Controls
- Manufacturer #: BMPLUS-3000
- Number of Stages: 2 Heat/2 Cool
- Number of Zones: 3
- Operating Temperature: -20 def F to 160 deg F
- Shape: Rectangular
The BMPlus Zone Control System allows you to easily upgrade an inefficient single zone HVAC system, into a Multi-zone, Energy savings, Comfort producing, HVAC system. The Superior Design, Intuitive Firmware, Simple Setup Options, Easy to Understand wiring and Backwards Compatibility, makes the BMPlus Zoning system the Contractors dream. Combined with EWC Motorized Dampers and any off-the-shelf Thermostats, EWC Controls sets another high standard in the residential & light commercial Forced Air Zoning Industry.
- Features
- MODULE TO MODULE FACTORY POWER WIRING: The BMPlus 3000 includes Factory Power Wiring on all expanded systems. The 24 vac power to the expansion modules is fed through the bus cable. This simplifies your wiring and minimizes the chances of reversing polarity.
- DUAL FUEL COMPATIBLE: The BMPlus 3000 is compatible with Dual Fuel Heat Pumps. Dual Fuel kits are not required. Select staging based on Adjustable Time Delay or an Optional Outside Air temperature Sensor. The intelligent firmware does the rest.
- SHORTED ZONE FEATURE FIRMWARE: This feature allows the BMPlus to ignore demands from a zone thermostat that is putting out simultaneous demands for heat & cool. A condition most likely due to a short in the field wiring, incorrect wiring, or a defective thermostat. The BMPlus will honor any legitimate demands from any other zone(s), except the shorted zone. When the problem is identified and repaired, the BMPlus 3000 will automatically recognize that zone
- Off, 7 to 42 minute staging time delay settings
- 7 to 42°F. outside air changeover.
- Operates with multi stage heatpumps.
- Adjustable differential limit control.
- Second stage 50% zone rule saves energy
- Status LED's are included on all modules.
- Simplified wiring and easy system setup.