Honeywell SV9602P4840/U Straight-Through Hot Surface Ignition Control
HONSV9602P4840U
MFG #: SV9602P4840/U
- Domestic / Import: Import
- End Style: NPT
- Ignition Type: Intermittent Hot Surface Pilot
- Nominal Size: 3/4 in
- Pressure Rating: 1/2 psi
- Dimensions: 4.1 in L x 3.2 in W x 4.9 in H
- Gas Type: LP
- Manufacturer: Honeywell
- Manufacturer #: SV9602P4840/U
- Type: Straight-Through
The SmartValve® System Controls combine gas flow control and electronic intermittent pilot sequencing functions into a single unit. This product family offers several different intermittent pilot sequences for a wide range of applications. The specific application of the SmartValve System is the responsibility of the appliance manufacturer. They are directly compatible with the Q3450 or Q3480 Intermittent Pilot burners used with the original controls on the appliance.
SmartValve® Hot Surface Ignition Control, Straight-Through, 3/4 in Nominal, NPT, 1/2 psi, Intermittent Hot Surface Pilot Ignition, LP, -40 to 175 deg F Ambient, 4.1 in L x 3.2 in W x 4.9 in H, Import
SmartValve® Hot Surface Ignition Control, Straight-Through, 3/4 in Nominal, NPT, 1/2 psi, Intermittent Hot Surface Pilot Ignition, LP, -40 to 175 deg F Ambient, 4.1 in L x 3.2 in W x 4.9 in H, Import
- Features
- Suitable for a wide range of gas-fired appliances including residential furnaces, roof-top furnaces, residential boilers, unit heaters, infrared heaters, space heaters and commercial cooking unit
- Ignition sequence includes timed trial for ignition
- 0 to 90 deg in any direction from the upright position of the gas control knob, including vertically mounting
- Electrical rating: 24 VAC
- Flame failure response time: 1.6 sec at 3 uA
- 50/60 Hz frequency
- Intermittent pilot ignition sequence
- 30 sec pre-purge
- Ignition trials to lockout: Continuous retry
- 90 sec ignition trial
- Typical ignition hardware: Q3450 and Q3480
- Step opening characteristic
- Pressure regulator setting: Full rate 10 in w.c., step setting: 1.4 in w.c. non-adjustable
- Capacity: Maximum at 1 in PD - 300 cu-ft/hr, maximum - 415 cu-ft/hr and minimum - 30 cu-ft/hr
- 1/8 in NPT pressure tapping
- Tradeline value: Universal