Honeywell Protectorelay® R8184G4033/U Oil Burner Control, 120/240 VAC, 3.7 to 7.4 A, Intermittent Ignition, Domestic
HONR8184G4033U
MFG #: R8184G4033/U
- Amperage Rating: 3.7 to 7.4 A
- Domestic / Import: Domestic
- Ignition Type: Intermittent
- Voltage Rating: 120 / 240 VAC
- Dimensions: 4-3/8 in H x 4 1/8 in W x 2 1/2 in D
- Manufacturer: Honeywell
- Manufacturer #: R8184G4033/U
- Mounting Type: Junction Box
- Temperature Rating: -40 to 130 deg F
The TRADELINE intermittent ignition oil primary control operates the oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat from the thermostat. Through a C554 Cad Cell Flame Sensor, the R8184 monitors the burner flame and shuts down the system on ignition failure or on flame failure during the run cycle. A light emitting diode (LED) on the terminal strip lights when the safety switch opens to provide safety shutdown indication. A manual reset button is provided to reset the safety switch after lockout. For convenience in system maintenance, the safety switch can be manually opened using a lever on the front of the control. Clock thermostats that power the clock through the primary control transformer will lose time during lockout unless backup batteries are installed.
Protectorelay® Oil Burner Control, 120/240 VAC, 3.7 to 7.4 A, Intermittent Ignition, -40 to 130 deg F, Junction Box Mount, 4-3/8 in H x 4 1/8 in W x 2 1/2 in D, Domestic
Protectorelay® Oil Burner Control, 120/240 VAC, 3.7 to 7.4 A, Intermittent Ignition, -40 to 130 deg F, Junction Box Mount, 4-3/8 in H x 4 1/8 in W x 2 1/2 in D, Domestic
- Features
- Provides automatic, no recycling control of an intermittent ignition oil burner system
- Controls oil burner, oil valves (if desired) and the ignition transformer in response to a call for heat
- Solid state flame sensing circuit
- LED on terminal strip indicates system lockout
- Remote lockout indication (available on some models)
- Enclosed safety switch with external reset button
- Manual trip lever opens safety switch for system maintenance
- Mounts on standard 4 x 4 in junction box select models may be mounted directly on burner housing
- C554A cadmium sulfide flame detector and 24 VAC thermostat required
- 22.2 to 44.4 A at 120 to 240 VAC for locked rotor